CE marking and EU declaration of conformity for lifts

The CE marking is affixed visibly, legibly and indelibly in every lift car before the lift is placed on the market, followed by the number of the notified body involved (Art. 13(3), (4) and (6) of the Bulgarian lifts essential-requirements ordinance). The installer draws up the EU declaration of conformity and keeps it for 10 years (Art. 17(3)–(4)).

In this article
  1. Who affixes the CE marking on a lift
  2. Where and how the marking is affixed
  3. What the EU declaration of conformity for a lift contains
  4. Which documents accompany the lift
  5. Why the marking matters for registration and inspections

Who affixes the CE marking on a lift

Under the Ordinance on the Essential Requirements and Conformity Assessment of Lifts and Safety Components for Lifts, responsibility lies with the “installer” – the person who takes responsibility for the design, manufacture, installation and placing on the market of the lift (§ 1(6) of the Additional Provisions).

The installer carries out or arranges a conformity assessment procedure under Art. 10, and only once conformity is shown does it draw up the EU declaration of conformity and affix the CE marking (Art. 17(2)–(3)). By drawing up the declaration it assumes responsibility for the lift’s compliance (Art. 12).

For safety components built into the lift, the same duties rest with their manufacturer (Art. 23).

Where and how the marking is affixed

  • Place: in each lift car (Art. 13(4)). On safety components, on the component itself or, where that is not possible, on a permanently attached label.
  • Form: visible, legible and indelible (Art. 13(4)).
  • Timing: before the lift is placed on the market (Art. 13(3)).
  • Notified body number: the CE marking is followed by the number of the body involved in module D, E, G, H1 or final inspection (Art. 13(6)). The number is affixed by the body or under its instructions (Art. 13(7)). Every lift procedure under Art. 10 includes at least one of these stages.
  • Additional marks: the marking and the number may be followed by a mark indicating a special risk or use (Art. 13(8)).

The car must also carry a plate stating the rated load in kilograms and the maximum number of passengers (Annex 2, point 5.1). The lift must bear a type, serial or other identification number and the installer’s name and postal address, with contact details in Bulgarian (Art. 18).

What the EU declaration of conformity for a lift contains

The declaration follows the model in Annex 5, Section II, and contains:

  1. the name and address of the installer and, where applicable, its authorised representative;
  2. a description of the lift, its type or series, serial number and the address where it is installed;
  3. the year of installation;
  4. the provisions it complies with and a statement of conformity with EU harmonisation legislation;
  5. the harmonised standards applied, where relevant;
  6. the name, address and number of the notified body and details of its certificate – EU-type examination, unit verification, final inspection or quality-system approval;
  7. the name and position of the signatory, place, date and signature.

If the declaration is not in Bulgarian, it must be translated into Bulgarian (Art. 11(4)). Where several EU acts apply to the lift, a single declaration is drawn up (Art. 11(5)).

Which documents accompany the lift

DocumentLegal basisRetention by the installer
EU declaration of conformityArt. 19(2)10 years after placing on the market (Art. 17(4))
Instructions in Bulgarian with drawings and diagrams, and a logbook for repairs and checksArt. 19(1); Annex 2, point 6.2–
Technical documentationArt. 17(2)10 years (Art. 17(4))
Quality-system approval, where applicableArt. 17(4)10 years

Why the marking matters for registration and inspections

The Ordinance on the Safe Operation and Technical Supervision of Lifts ties operation directly to the marking and the declaration:

  • the user may allow operation only when conformity is attested by a declaration and marking (Art. 4(2));
  • registration is due within 20 days of the declaration being issued, and the declaration is attached to the application (Art. 20(1) and (3)(7));
  • the initial inspection checks that the lift and its safety components bear the marking (Art. 25a(2)). This inspection is needed if the lift was not put into service for more than 6 months after the certificate or declaration (Art. 24(1)(1));
  • without the marking, the maintenance company must not allow the lift to operate (Art. 7a(5)), and the DAMTN (State Agency for Metrology and Technical Surveillance) Chief Directorate “Inspection for State Technical Supervision” (GD IDTN) orders it to stop (Art. 30(1)(6)).

ESTIMA KM is Notified Body No. 1829 for lift safety components (module H; B and C2 for devices to prevent falls) – see notified body No. 1829 and our articles on conformity assessment procedures and registering a new lift.

Need conformity assessment for a lift?

Call or write to us.

Sofia: +359 2 951 54 53 Notified Body 1829

Write to office@estimakm.com

Sources

This article is for information and does not replace the text of the legal act.

Frequently asked questions

Can the CE marking be only in the machine room?

No. For lifts it is affixed in each lift car (Art. 13(4) of the essential-requirements ordinance).

Whose number is next to the CE mark in the car?

The notified body involved in module D, E, G, H1 or final inspection (Art. 13(6)).

Must the EU declaration be in Bulgarian?

Yes. When the lift is placed on the market in Bulgaria and the declaration is not in Bulgarian, it must be translated (Art. 11(4)).

How long is the declaration kept?

The installer keeps it with the technical documentation for 10 years after placing the lift on the market (Art. 17(4)).