Static and dynamic load testing of lifting equipment

Unless the manufacturer's instructions say otherwise, the static test of lifting equipment lasts 10 minutes with a load 25% above the rated capacity, and the dynamic test uses a load 10% above it (Art. 113(2) and 114(2) of the Bulgarian Ordinance on lifting equipment). Cranes, trolleys, electric hoists, excavators and mobile elevating work platforms need an inspection with both tests every 8 years (Art. 108(1)(3)).

In this article
  1. When are static and dynamic tests carried out?
  2. How is the static test performed?
  3. How is the dynamic test performed?
  4. Which tests are required after a repair?
  5. How do I prepare for an inspection with load tests?

When are static and dynamic tests carried out?

Under the Ordinance on the Safe Operation and Technical Supervision of Lifting Equipment, both tests are part of the following inspections:

  • the initial inspection after registration (Art. 110(1)(5) and (6));
  • the periodic inspection with load tests — every 8 years (96 months) for cranes, trolleys, electric hoists, excavators and work platforms (Art. 108(1)(3) and (8));
  • inspections after reconstruction, after more than one year out of use, after replacing or repairing load-bearing elements and mechanisms, and after relocation to another workplace (Art. 111(1) with Art. 108(1)(4)–(7)).

The regular one- or two-yearly periodic inspection does not include a load test. It covers the documents, installation, a visual examination and a functional test (Art. 111(1) with Art. 110(1)(2)–(4)). At inspections requested by the user and at unannounced inspections, the tests are done according to the request or the body's judgement (Art. 111(3)).

There are exceptions for new and reconstructed equipment. At the initial inspection of equipment placed on the market fully assembled, no tests are done if no more than 24 months have passed since the declaration of conformity was issued (Art. 110(2)). The same applies after a reconstruction if the declaration of conformity for the reconstructed equipment is no more than 24 months old (Art. 111(2)).

How is the static test performed?

The static test follows the operating instructions and, for cranes, also clause 3.3.1 of BDS ISO 4310 (Art. 113(1)). The Ordinance sets the following:

  • if the instructions do not set the load and duration, a load 25% above the rated capacity, held for 10 minutes (Art. 113(2));
  • for detachable lifting attachments, a load 50% above their rated capacity (Art. 113(3));
  • jib cranes and boom-type work platforms are tested at maximum boom outreach, cantilever-type platforms at maximum cantilever outreach (Art. 113(4));
  • a dynamometer may be used instead of a test load (Art. 113(5)).

The test is passed if the load or platform does not sink and no cracks, broken elements, flaking paint, permanent deformation or damage affecting safety are found that can be seen without special instruments (Art. 113(2)).

How is the dynamic test performed?

The dynamic test also follows the operating instructions and, for cranes, clause 3.3.2 of BDS ISO 4310 (Art. 114(1)). If the instructions contain no other requirements, a load 10% above the rated capacity is lifted, lowered and moved several times, checking the mechanisms and brakes (Art. 114(2)).

The test is passed if the mechanisms are not damaged and the drives and brakes work in line with the specified operating modes (Art. 114(2)).

TestLoadMethodLegal basis
Static — equipment+25% above rated capacity, unless the instructions say otherwise10 minutes, load must not sinkArt. 113(2)
Static — detachable lifting attachments+50% above rated capacityloadingArt. 113(3)
Dynamic+10% above rated capacity, unless the instructions say otherwiserepeated lifting, lowering and travelArt. 114(2)

Which tests are required after a repair?

The company that repairs or reconstructs the equipment keeps a technical file for at least 10 years. It includes the records of static and dynamic tests after repairing or replacing load-bearing structures and elements, hoisting mechanisms, load hooks, ropes or pulley blocks, and, for personnel hoists, after replacing the hoisting machine, suspension ropes, overspeed governor or safety gear (Art. 40(1)(6) and (7)).

The repairer gives the user two copies of these documents (Art. 40(2)). The user attaches them to the written request for the additional inspection after a replacement or repair (Art. 108(4)).

For cranes in service for more than 16 years, the technical supervision body may require non-destructive testing of the load-bearing elements or hooks for cracks. It is done by persons under Art. 47, at the user's expense (Art. 112).

How do I prepare for an inspection with load tests?

The user sends a written request to the body the equipment is registered with. A periodic load-test inspection is carried out within 6 weeks, and additional inspections under Art. 108(1)(4)–(7) within 2 weeks of the request (Art. 108(2)). The date is announced at least 5 days in advance (Art. 108(3)), and the responsible person and/or the maintenance company attend (Art. 108(7)).

Runways must be designed for the loads arising in the tests under Art. 113 and 114 (Art. 27(1)(1)). The results are entered in the logbook (ревизионна книга) together with a statement on fitness for use and the date of the next inspection (Art. 116(1)).

ESTIMA KM Ltd carries out load-test inspections as a technical supervision body holding licence No. 485. See technical supervision of lifting equipment, and for all intervals the article Crane and hoist inspections: intervals.

Need an inspection of lifting equipment?

Call or write to us.

Sofia: +359 2 951 54 53 Lifting equipment Work out the date

Sources

This article is for information and does not replace the text of the legal act.

Frequently asked questions

Can the static test be done without a test load?

Yes. The Ordinance allows the static test to be carried out with a dynamometer instead of a load (Art. 113(5)).

Is a load test part of every periodic inspection?

No. A regular periodic inspection covers the checks in Art. 110(1)(2)–(4) without a load test (Art. 111(1)). Static and dynamic tests are done at the 8-year periodic inspection and at the additional inspections under Art. 108(1)(4)–(7).

Is a new crane load-tested at the initial inspection?

Not if it was placed on the market fully assembled and its declaration of conformity is no more than 24 months old (Art. 110(2)). Otherwise the initial inspection includes static and dynamic tests (Art. 110(1)(5) and (6)).

What test load applies to detachable lifting attachments?

The static test of detachable lifting attachments uses a load 50% above their rated capacity (Art. 113(3)).